Superparamagnetic nanosensors for the detection of cardiovascular biomarkers by magnetic resonance relaxometry and imaging

Superparamagnetic nanosensors for the detection of cardiovascular biomarkers by magnetic resonance relaxometry and imaging Advanced Imaging Unit. Dpt of Epidemiology, Atherothrombosis and Imaging. Spanish Cardiovascular Research Centre (CNIC) and Spanish Pulmonary Research Centre (CIBERES). C/ Melchor Fernández-Almagro 3, 28029 Madrid.
bsalinas@cnic.es Purpose: Magnetic Resonance Relaxometry (MRR) and Magnetic resonance imaging
(MRI) are increasingly accessible techniques for in vitro and in vivo diagnosis and
quantification. With this in mind our aim was to develop two different
superparamagnetic nanosensors for the detection and quantification of Ca2+ ions and
Matrixmetalloproteases 2 and 9 (MMPs). Both nanosensors are based in the same
principle, i.e. the change in the relaxometric properties of the particles due to the
interaction with the sample.
Materials and Methods: Iron oxide nanoparticles (SPIO) were synthesised by thermal
decomposition of organic precursors. These SPIOs were reacted with 2-
(acryloyloxy)ethyl succinate by olefin metathesis in presence of Grubbs-Hoveyda 2nd
generation catalyst. Water stable NPs generated in just one step were redispersed in
aqueous solution with different Ca2+ concentrations. The formation of clusters between
the terminal carboxyl groups and the cations generate changes in the r2 relaxometric
values which subsequently were observed and demostrated in MRI. The selectivity was
checked by measuring with other important ions like Al3+,Mg2+,NH4+,K+,Cu2+ and Na+ by
MRR and MRI. For the synthesis of the second nanosensor, for MMP detection and
quantification, a different approach was used. SPIOs were oxidized with KMnO4,
generating water stable nanoparticles with azelaic acid as surfactant. The terminal
carboxylic groups present in the surface were activated with EDC and sulfo NHS and
conjugated with gelatin. The relaxivity of these NPs was studied in presence of MMPs
2 and 9, along time, by MRM and MRI.
Conclusions: We developed, by new functionalization tecniques, two new
superparamagnetic nanosensors. The first one is selective of Ca2+ versus Al3+, Mg2+,
NH +
4 , K+, Cu2+ and Na+. It allows for the quantification of calcium due to the changes in its physicochemical properties, this has been confirmed by imaging and analytical techniques. The second nanosensor is able to selectively quantify the amount of MMP2 and -9 with a detection limit as low as 1 ng/mL, smal er than most commercial kits, without any special sample preparation. Also for this sensor various techniques have been used to demonstrate it mechanism of action. Finally we wil show the possibilities of both nanosensors for in vivo use.
References:
1.-B. Salinas, J. Ruiz-Cabello, I. Bilbao, M. P. Morales, E. G. Rodríguez, P. Martin3, F.
Herranz. ACS Nano, submitted.
2.-B. Salinas; J. Ruiz-Cabel o; M. P. Morales; F. Herranz. Bioinspired, Biomimetic and
Nanobiomaterials
. 2012, 1 - 3, 166 - 172.
3.-F. Herranz; M.P. Morales; A. Roca; M. Desco; J. Ruiz-Cabel o. Chem. Eur. J. 2008,
14, 9126-9130.
4.- F. Herranz; M. P. Morales; A. Roca; R. Vilar; J. Ruiz-Cabello. Contrast Media Mol.
Imaging.
2008, 3, 215-222

Source: http://www.esmr.eu/Abstracts%202013/Abstract%20EMRF%202013%20Salinas%20Beatriz.pdf

Microsoft word - econ loss & designliability dco 2nd draft 24th sep 2006.doc

Developments in the Law of Economic Loss and Liability under Design & Build Situations ORGANISED BY Society of Construction Law (Singapore) 15th – 17th October 2006, Grand Copthorne Waterfront Hotel, Singapore by COLIN Y.C. ONG 1 General Introduction to the Law of Economic Loss The current position depicting the law of economic loss even among Commonwealth coun

R15120 - piping accessories

SECTION 15120 - PIPING ACCESSORIES PART 1 GENERAL 1.01 Drawings and general provisions of the contract, including General Conditions and Division 1 Specification Sections, apply to work of this Section. Where contradictions occur between this Section and Division 1, the most stringent of the two shall apply. Manufacturer's Data - Piping Accessories: Submit manufacturer's data on the following

Copyright © 2010-2014 Online pdf catalog