1016523l-taabw.pmd

Easy-to-install wireless liquid level alarm system with auto-reset and
battery backup features.

The Tank Alert® ABW alarm system features a battery operated wireless
transmitter
that is placed in a tank (up to 150 feet away from the indoor alarm).
When the high water alarm float switch activates, the transmitter sends a
signal and sounds the indoor alarm warning of a potentially threatening liquid
level condition. The horn can be silenced, but the alarm light remains on until
the condition is remedied. Once the condition is cleared, the alarm will
automatically reset.
The Tank Alert® ABW alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, effluent filters, andother water applications.
Shown with optional mounting bracket.
 NEMA 1 enclosure rated for indoor use.
VOLTAGE FOR 120 VAC MODEL:
Primary: 120 VAC, 60 Hz, 2.4 watts max.
 Red "alarm" light and green "power on" light, alarm "test" switch, BATTERY BACKUP POWER: 9 VDC
ALARM ENCLOSURE: 6 x 4 x 2.25 inch
 Alarm horn sounds at 87 decibels at 10 feet (3 meters).
(15.24 x 10.16 x 5.71 cm), NEMA 1 plastic.
 If primary power fails, the alarm system continues to work due to ALARM HORN: 87 decibels at 10 feet
battery backup feature. Battery Backup Power: 9 VDC.
(Battery not included.)  Package includes standard SJE MilliAmpMaster™ control switch POWER CORD: 6 foot (1.8 meter)
with 10 feet (3.04 meters) of cable with transmitter.
 Switching mechanism operates on low voltage and is isolated OPTIONAL FLOAT SWITCH CONNECTION
from the power line to reduce the possibility of shock.
TERMINAL:
 Loss of signal alarm. After 24 hours without a signal the red LED will begin flashing. After 7 days without a signal the alarm willsound.
FCC ID #: SCP TAABW01
 External terminal block for an optional local alarm float.
This device complies with Part 15 of the FCC Rules. Operation is subject to the followingtwo conditions:  Wireless transmitter with up to 150 foot range.
 This device must accept any interference received, including interference that may Long life lithium battery (recommended replacement 2 years). Contact SJE-Rhombus Customer Service department for replacement lithiumbattery.
 Transmitter transmits once per hour or when the float position is  Alternate float switch models and configurations SEE BACKSIDE FOR ORDERING INFORMATION.
SEE PRICE BOOK FOR LIST PRICE.
Easy-to-install wireless liquid level alarm system with auto-reset and battery backup features.
TA ABW-01H (120 VAC High w/10ft SJE MilliAmpMaster™ pipe clamp N.O.) TA ABW-01H (120 VAC High w/10ft Sensor Float® internal weight N.O.) TA ABW-01H (120 VAC High w/10ft Sensor Float® pipe clamp N.O.) TA ABW-01H (120 VAC High w/10ft Sensor Float® cable weight N.O) TA ABW-01H (120 VAC High w/10ft SJE MilliAmpMaster™ pipe clamp N.O.) TA ABW-01H (120 VAC High w/10ft Sensor Float® internal weight N.O.) TA ABW-01H (120 VAC High w/10ft Sensor Float® pipe clamp N.O.) TA ABW-01H (120 VAC High w/10ft Sensor Float® cable weight N.O.) UL Listed component version, Vertical Reed Switch version, and normally closed versions also available.
Please contact an SJE-Rhombus® Customer Service Representative for details.
H = High Level
MASTER CARTON holds 5 boxed units.
SEE PRICE BOOK FOR LIST PRICE.

Contact SJE-Rhombus Customer Service department for replacement lithium battery.
FCC ID #: SCP TAABW01
VOLTAGE FOR 120 VAC MODEL:
Primary: 120 VAC, 60 Hz, 2.4 watts max. (alarm condition) the FCC Rules. Operation is subjectto the following two conditions: BATTERY BACKUP POWER: 9 VDC
ALARM ENCLOSURE: 6 x 4 x 2.25 inches (15.24 x 10.16 x 5.71 cm),
ALARM HORN: 87 decibles at 10 feet (3 meters)
POWER CORD: 6 foot (1.8 meter)
interference that may causeundesired operation.
OPTIONAL FLOAT SWITCH CONNECTION TERMINAL: For float switch
connection only (voltage across terminals is 8-9 VDC) 1-888-DIAL-SJE (1-888-342-5753)  Fax 218-847-4617

Source: http://www.sjerhombus.us/uploads/1016523L-TAABW-Sub.pdf

Test

G. Bala Krishna Pai Versus Sree Narayana Medical Mission General Hospital CMCL 930a NATIONAL CONSUMER DISPUTES REDRESSAL COMMISSION, NEW DELHI HON’BLE MR. JUSTICE S.N. KAPOOR, PRESIDING MEMBERSree Narayana Medical Mission General Hospital And T.B. Clinic & Ors. [From the order dated 12.3.1996 in Complaint No. 103/1996 of the State Consumer Law—Medical Negligence—Claim for com

Microsoft word - 54-temanni-jfim 2005.doc

Combinaison des données d’expressions génique et des données cliniques pour améliorer la qualité de la prédiction de la survie à 5 ans de patients atteints de cancer. Mohamed-Ramzi Temanni1, Blaise Hanczar1, Jean-Daniel Zucker1 1Laboratoire d’Informatique Médicale et Bioinformatique (LIM&BIO), UFR SMBH, Université Paris 13, France. Journées Francophones d

Copyright © 2010-2014 Online pdf catalog